Heating mats for outdoor applications

						
We offer special mats 300-400 W/m² for outdoor applications in which the cable isn’t fixed to material, but is connected by fastening strips. After placement in sand the cable is thus better surrounded by backfill.
Ice and snow melting
Ice and snow melting

The heating can be provided by a heating circuit as well as a heating mat. For thoroughfares which are walked on, the heating element is placed in a sand bed or into a concrete slab, while in the case of stairs, terraces and similar areas the element is embedded into bonding cement. In thoroughfares used for driving, we unambiguously recommend that the heating element is placed into a concrete slab which will protect the heating cable from damage when the thoroughfare is used by a car.

For thoroughfares which aren’t used by vehicles (pavements), the heating cable can only be placed into a sand bedFor the heating of outdoor surfaces a wattage of 300-400 W/m² is installed. Such a high output is necessary for the system to function correctly even at temperatures far below freezing point. Also, correct regulation is very important – as it will bring the heating system into operation as soon as there is a danger of ice formation. This means a regulation system which registers not only the temperature but also the presence of moisture in the area monitored. If the system is controlled manually by the user and is brought into operation at a time when the surface concerned has already been covered with a layer of snow, this snow can take more than 12 hours to melt (depending on the height of the layer of snow). It is necessary to realize that the heating cable is placed in the ground, which has a great ability to absorb heat, and also that a large amount of energy is needed for the transformation of snow into water – so called latent heat. The installation of supplementary thermal insulation into the base composition is inefficient with a few exceptions. 

For these applications we offer robust ADPSV, MST and MDT cable mats with protective sheathing. MDT mats are also suitable for installation in asphalt.

Ice and snow melting
Pavement
MAPSV Cable construction
MADPSP Cable construction
Ice and snow melting – Heating cable mat
Ice and snow melting
Ice and snow melting
Ice and snow melting

ADPSV 300 W/m²

Type ADPSV 300 W/m² Output Area Width Length Cat. No.
[W] [m²] [m] [m]
ADPSV 300-1 300 1.0 0.5 2.0 5510505
ADPSV 300-1.5 450 1.5 0.5 3.0 5510510
ADPSV 300-2 600 2.0 0.5 4.0 5510515
ADPSV 300-2.5 750 2.5 0.5 5.0 5510520
ADPSV 300-3 900 3.0 0.5 6.0 5510525
ADPSV 300-3.5 1050 3.5 0.5 7.0 5510530
ADPSV 300-4 1200 4.0 0.5 8.0 5510535
ADPSV 300-5 1500 5.0 0.5 10.0 5510540
ADPSV 300-6 1800 6.0 0.5 12.0 5510545
ADPSV 300-7 2100 7.0 0.5 14.0 5510550
ADPSV 300-9 2700 9.0 0.5 18.0 5510555
ADPSV 300-10 3000 10.0 0.5 20.0 5510560

MDT 400 W/m²

Type MDT 400 W/m² Output Area Width Length Cat. No.
[W] [m²] [m] [m]
MDT 400-0.9 340 0.9 0.75 1.1 5510005
MDT 400-1.4 570 1.4 0.75 1.9 5510010
MDT 400-2.3 880 2.2 0.75 2.9 5510015
MDT 400-2.6 1030 2.6 0.75 3.4 5510020
MDT 400-3.3 1320 3.3 0.75 4.4 5510025
MDT 400-4.3 1700 4,3 0.75 5.7 5510030
MDT 400-4.7 1880 4.7 0.75 6.3 5510035
MDT 400-6.1 2450 6.1 0.75 8.2 5510040
MDT 400-7.3 2900 7.3 0.75 9.7 5510045
MDT 400-8.5 3400 8.5 0.75 11.3 5510050
MDT 400-13.0 5200 13.0 0.75 17.3 5510055
MDT 400-18.4 7350 18.4 0.75 24.5 5510060

MDT 400 W/m² - 400V

Type MDT 400 W/m² - 400V Output Area Width Length Cat. No.
[W] [m²] [m] [m]
MDT 400-1.5 600 1.5 0.75 2.0 5510105
MDT 400-2.5 1000 2.5 0.75 3.3 5510110
MDT 400-3.8 1520 3.8 0.75 5.1 5510115
MDT 400-4.5 1800 4.5 0.75 6.0 5510120
MDT 400-5.8 2300 5.8 0.75 7.7 5510125
MDT 400-7.4 2970 7.4 0.75 9.9 5510130
MDT 400-8.3 3300 8.3 0.75 11.0 5510135
MDT 400-10.6 4250 10.6 0.75 14.2 5510140
MDT 400-12.8 5100 12.8 0.75 17.0 5510145
MDT 400-14.8 5900 14.8 0.75 19.7 5510150
MDT 400-22.5 9000 22.5 0.75 30.0 5510155

MST 300 W/m² - 0.5 m

Type MST 300 W/m² Output Area Width Length Cat. No.
[W] [m²] [m] [m]
23MST 300/12-0.5 3600 12.0 0.5 24.0 5501145
23MST 300/15-0.5 4500 15.0 0.5 30.0 5501150
23MST 300/20-0.5 6000 20.0 0.5 40.0 5501155

ECOFLOOR accesories

Type Description Quantity supplied Cat. No.
Gutter clip 100 1 package = 25 pcs 1 package 2350000
Gutter clip 150 1 package = 25 pcs 1 package 2350007
Downpipe cable clip 1 package = 25 pcs 1 package 2350003
Chain 1 package = 10 m 1 package 2350004
Grufast 1 unit = 10 m / 4.5 m2 1 unit 4200013
Cable Fix 1 unit = 10 m 1 unit 4200016
Copper end piece intended as an end piece for a flexible tube ('gooseneck'): outer diameter 11.4 mm / inner diameter 8.5mm – used to prevent sealant (anhydrite, concrete) from entering the gooseneck containing the floor probe and to improve the transfer of heat to the thermistor of the probe = more precise measurement of floor temperatures 1 unit 2350021
Raster separation film 1 unit = 50 m 1 unit 6651032
Plastic cable clip 1 package = 600 pcs 1 package 1200003
Plastic clip 1 package = 50 pcs 1 package 1200000
Installation tool for the comfortable installation of plastic clips 1 unit 1200010
T-strip 1 package = 20 pcs 1 package 2350009
Kit no. 1 for PV cable repair 1 kit 5030121
Kit no. 2 for ADSV, ASL1P, PSV, CM Mat LD and LDTS cable repair 1 kit 5030122
Kit no. 3 for MADPSP, MAPSV, MST, MDT and ADPSV cable and mat repair 1 kit 5030123
Kit no. 4 for connection and termination of self-limiting cables 1 kit 5030124
Kit no. 5 for MADPSP installed under asphalt 1 kit 5030125
Kit no. 6 termination of PC/PC-S cables 1 kit 5030126
Aluminium tape width 50 mm, length 50 m 1 pcs 2832515
SYFOK-P 1 package = 20 m 1 package 2350012
1 package = 10 m 1 package 2350013
Spacing grip 1 package = 25 pcs 1 package 2350014
C-shaped copper 1 package = 25 pcs 1 package 2350005
TOPlist